The product mentioned refers to a complete industrial forced-circulation oil heating system (Hotstart OLE Oil Heating System), specifically designed for large engines or compressors used in environments with a high risk of explosion (Hazardous Locations / HazLoc).
Key technical specifications for the OLE30604-630 series:
• Equipment type: Oil heating system with an integrated recirculation pump.
• Electrical configuration: 480V, 3-phase, 60Hz power supply.
• Heating capacity: 6 kW.
• Pump performance: 3 HP (horsepower) motor with a pump providing a flow rate of 20 GPM (approximately 75 liters/minute).
• Control relay: Equipped with a 24 VDC control coil.
• Hazardous environment certification: Meets strict North American safety standards – Class I, Division 1 & 2, Group D.
Role and functionality:
The system prevents the degradation of oil viscosity during periods of inactivity and eliminates the need for a separate pre-lubrication pump. By maintaining a constant temperature above the dew point, it prevents condensation from forming in the oil sump, ensuring reliable startups and minimizing wear on internal components in cold or humid climates.
| Lot # | ERP code |
| 1332 | 6099-0025 |
| 1324 | 6099-0026 |
| 1325 | 6090-0027 |
| 1334 | 6099-0032 |
SN available: 43266, 43815, 43816, 44244,